American Dryer Corp None Clearing CREDIT/CLEARING Cycle, Accessing Coin Vault, Wrinkle Guard

Models: None

1 76
Download 76 pages 31.81 Kb
Page 11
Image 11

G. CLEARING CREDIT/CLEARING CYCLE

In Coin Mode, credit can be cleared from the Phase 7 dual microprocessor controller (DMC) computer by pressing and holding the “PAUSE” key while entering the following key combination: “HI-HI-HI-LO-LO- MED”. The combination is the “HI” key three (3) times followed by the “LO” key two (2) times and then the “MED” key one (1) time. Wait 1-second for the Phase 7 DMC (computer) to prompt the user with “CLEAR CREDIT?” If you want to proceed, simultaneously press the “PAUSE” key and one (1) of the remaining keys. This will clear the credit. A flowchart of this procedure has been provided in Section VI of this manual.

A cycle in Free Mode can be cleared by first pausing a cycle and then pressing the “PAUSE” key once again to clear the cycle.

H. ACCESSING COIN VAULT

The coin vault can be accessed by placing the program switch into the “UP” position. Once the program switch is in the “UP” position, press the “HI” key. The Phase 7 DMC (computer) will now display the amount of money in the coin vault. Press the “HI” key again and the Phase 7 DMC (computer) will ask to “CLEAR COIN VAULT TOTAL?” Press “PAUSE” for “NO” or press “MED” for “YES”.

I. CLEARING FAULT RECORDS AND CREDIT

This feature allows the user to reset the coin vault, clear any credit still available for a cycle and ALL fault records. In order to activate this feature the Phase 7 DMC (computer) needs to be powered down and then restarted. Immediately after power has been applied to the Phase 7 DMC (computer) press and hold the “PAUSE” key and “HI” key simultaneously. The Phase 7 DMC (computer) will prompt the user with the following message “CLEAR FAULT RECORDS AND CREDIT?” Pressing “PAUSE” and any other key will indicate a YES, while pressing any key other than “PAUSE” will indicate a NO. Once the fault records, coin vault and credit are cleared, there is no way of restoring this information.

J. WRINKLE GUARD

This program keeps items wrinkle-free when they are not removed from the dryer promptly at the end of the drying cycle and/or cooling cycle.

When the drying and cooling cycles are completed, the dryer will shut off, the tone will sound, and the liquid crystal display (L.C.D.) will read “CYCLE DONE”. If the door is not opened, the Phase 7 DMC (computer) will wait an initial 15 minutes delay time. Once the initial 15 minute delay time has expired, the fan will start and the basket (tumbler) will rotate (without heat) for an ON time of 15-seconds. When the fan and basket start, the display will read “WRINKLE GUARD”. Immediately following the 15-second ON time, the Phase 7 DMC (computer) will go into a 5 minute OFF time at which point it will display “CYCLE DONE”. The Phase 7 DMC (computer) will repeat this process of 15-seconds “ON” and 5 minutes “OFF” until either the doors are opened or 99 minutes have elapsed, whichever comes first. Prior to each ON time, there is a 3-beep warning that the fan and basket (tumbler) rotation are about to start. The beeps at the end of the Wrinkle Guard Cycle can be programmed to be ON/OFF. Refer to page 14 for PL #01 – SELECT BUZZER MODE.

9

Page 11
Image 11
American Dryer Corp None Clearing CREDIT/CLEARING Cycle, Accessing Coin Vault, Clearing Fault Records and Credit