ACCESSING LOWER DRYER FAULT RECORDS
READY, INSERT |
|
0.25 ¢ TO START | FROM READY MODE |
| |
| TOGGLE PROGRAM |
| SWITCH TO UP |
PROGRAM MODE | POSITION. |
| PRESS "MED" TO ENTER |
| PROGRAM MENU. |
PL #01 CONTROL
SETTINGS
PL #07 FAULT RECORDING
PRESS "LO" ONE (1) TIME TO SCAN DOWN TO PL #07 FAULT RECORDING.
UPPER DRYER
FAULTS
PRESS "MED" TO ENTER PL #07 FAULT RECORDING.
PRESS "HI" TO SCAN UP TO LOWER DRYER FAULTS.
LOWER DRYER
FAULTS
1:HR=2:00 CODE= Exhaust Temp Probe Fault
2:HR=2:00 CODE= Exhaust Temp Probe Fault
Drying Temp 160°F, Cool Down Time 2 minutes, Cool
Down Temp 100°F
PRESS "MED" TO
PROCEED.
USE THE “HI” AND “LO”
KEYS TO SCAN
THROUGH THE LAST 5
FAULTS THAT THE
CONTROL BOARD
DETECTED.
FOR CYCLE
INFORMATION AT THE
TIME OF THE FAULT
OCCURRENCE, PRESS
THE “MED” KEY.
Note: Press "PAUSE" To exit
PL #07 FAULT RECORDING memory location.
59