Dual CoinAcceptor

Example No. 1: If the dryer is equipped with a 10¢/25¢ dual coin acceptor and the AMOUNT TO START (PL #06) is 50¢, the LO key AMOUNT FOR TOP OFF (PL #06) is 20¢, the LO key TIME FOR AMOUNT TO START (PL #05) is 20 minutes, and LO key TIME FOR TOP OFF is 10 minutes. After the initial AMOUNT TO START (PL #06) has been met, each additional 20¢ will yield 10 minutes and each additional 25¢ will yield 10 minutes with 5¢ left in escrow. Each time a 25¢ coin is inserted, the remaining 5¢ will be added to escrow. Once the amount in escrow reaches 20¢, another 10 minutes will be vended.

Settings: PL #06 (LEFT COIN DENOMINATION)

10

PL #06 (RIGHT COIN DENOMINATION)

25

PL #05 (TIME FOR AMOUNT TO START)

20

PL #05 (TIME FOR TOP OFF)

10

PL #06 (AMOUNT TO START)

50

PL #06 (AMOUNT FOR TOP OFF)

20

Formula: (AMOUNT TO START [PL #06]) = Vended Time is TIME FOR AMOUNT TO START (PL #05) 50¢ = 20 minutes

(AMOUNT FOR TOP OFF [PL #06]) = Vended Time is TIME FOR TOP OFF (PL #05)

20¢ = 10 minutes

Example No. 2: If the dryer is equipped with a 10¢/25¢ dual coin acceptor and the AMOUNT TO START (PL #06) is 50¢, the AMOUNT FOR TOP OFF (PL #06) is 50¢, the LO key TIME FOR AMOUNT TO START (PL #03) is 20 minutes, and the LO key TIME FOR TOP OFF is 20 minutes. After the initial AMOUNT TO START (PL #06) has been met, each additional 50¢ will yield 20 minutes.

Settings: PL #06 (LEFT COIN DENOMINATION)

10

PL #06 (RIGHT COIN DENOMINATION)

25

PL #05 (TIME FOR AMOUNT TO START)

20

PL #05 (TIME FOR TOP OFF)

10

PL #06 (AMOUNT TO START)

50

PL #06 (AMOUNT FOR TOP OFF)

20

Formula: (AMOUNT TO START [PL #06]) = Vended Time is TIME FOR AMOUNT TO START (PL #05) 50¢ = 20 minutes

(AMOUNT FOR TOP OFF [PL #06]) = Vended Time is TIME FOR TOP OFF (PL #05)

50¢ = 20 minutes

21

Page 23
Image 23
American Dryer Corp None user manual Dual CoinAcceptor