American Dryer Corp WDA-385 service manual D. No Display Condition

Models: WDA-385

1 57
Download 57 pages 20.54 Kb
Page 48
Image 48
D. No Display Condition

D. No Display Condition

1.Check power supply. (dryer voltage 110v, 208v, 220v ...)

2.Check for voltage across (L1) and (L2) of motor relay. (110v, 208v, 220v ...) For 3 phase machines, check across (L1) and (L3). If no voltage is evident, problem is bad wire(s) or termination from circuit breaker panel to top of motor contactor.

3.Check the .5 amp fuse(s) in the control box. If dryer is rated at 110v, 115v, or 120v there will only be one fuse. Voltages of 208v, 220v will have two (2) fuses. If blown, replace with P/N: 136057.

4.Check voltage across TB #8 and TB #6 (110v, 208v, 220v). If no voltage is evident, problem is bad wire or termination from TB #8 and TB #6 to the L1 and L2 connection on the motor relay.