E. "dSFL" Display Condition

E. "dSFL" Display Condition

When the display reads "dSFL" this condition indicates a fault in the microprocessor controllers heat circuit. This circuit includes the microprocessor controller, microprocessor temperature sensor (located in lint compartment) and wires to and from these two (2) points.

1.Check to see if microprocessor controller has 1/8 amp fuse on the board, if it does check with out ohm meter. If no continuity replace with ADC P/N: 136048. If fuse repeatedly burns out go to step 4.

2.Check for loose connection at the microprocessor sensor bracket harness connector (located in lint compartment), and the microprocessor 15 position connector at the microprocessor controller.

3.Discontinue power to dryer. Disconnect the microprocessor 15 position connector from microprocessor controller and locate connector holes no. 10 and 15. Disconnect sensor harness from sensor bracket assembly (located in the lint compartment). Check for continuity across each wire from harness connector in lint compartment to appropriate microprocessor 15 position connector hole (10 and 15). If no continuity, problem is break in wire or termination.

4.Check for continuity across each microprocessor sensor wire (microprocessor 15-position connector hole no. 10 and 15) to ground. If continuity is evident, problem is wire pinched to ground somewhere behind the front panel area.

5.If above procedures check out okay, problem is a defective microprocessor temperature sensor.