American Dryer Corp WDA-385 service manual B. Using A Manometer

Models: WDA-385

1 57
Download 57 pages 20.54 Kb
Page 53
Image 53
B. Using A Manometer

B. Using A Manometer

How To Use A Manometer

1.With dryer in non-operating mode remove plug on the gas valve pressure tap.

2.Attach plastic tubing to pressure tap. (fitting is supplied with manometer see illustration.)

3.Attach manometer to dryer using magnet.

NOTE: Place manometer in a position so that readings can be taken at eye level.

4.Fill manometer as shown in illustration to the zero (0) level.

5.Start dryer. With burner on take a reading.

A.Read water level at the inner tube. Readings should be taken at eye level.

B.Correct readings should be:

NATURAL GAS: 3.5 - 4.0 inches w.c. L.P. GAS: 11 -10.5 inches w.c.

6.If water column pressure is incorrect refer to "To Adjust Gas Pressure"

7.Reverse procedure for removing manometer.

49