AP120BC1000-3/ AP120BCF1300-3 Manual
30
2. MANUAL MODE - SOFT CHILL
F
INSTEAD OF AUTOMATIC you wish to select a MANUAL cycle, perform steps 1.a, 1.b, 1.c, 1.d
1.e, 1f and 1.g (above), except in step 1.c press button
,
instead of button . The
LED for "MANUAL" will then be steady "ON". The readouts in those steps will be the same as
before.
NOTE: Cycle time can be changed only in Cycle Programming mode. To change the
programmed cycle time for any cycle see the instructions on Pages 17 to 25.
h. Press the ("START/STOP") button to start the cycle.
The display will show briefly:
Then the display will show:
STARTING CYCLE . . .
alternating with
01:29
Will count
down
The MANUAL mode uses time and the air probe temperature to control the cycle.
The default total time for a soft cycle is 90 minutes. After the 90 minutes the unit will automatically
go into holding mode
03.07.2006 10:41 AM
AIR 1 75°F
AIR 2 76°F
AIR 3 74°F 01:29
R / CHICKEN 140°F
Y / ROAST BEEF 143°F
B / CHICKEN 141°F
G / ROAST BEEF 142°F
.
The display will show:
alternating with
00:00 Blinks
The operator can now end this cycle by pressing ("START/ STOP").
Then the display will show:
03.07.2006 10:41 AM
AIR 1 34°F
AIR 2 35°F
AIR 3 34°F 00:00
R / CHICKEN 40°F
Y / ROAST BEEF 40°F
B / CHICKEN 40°F
G / ROAST BEEF 40°F
OPERATING MODE
CHOOSE
OPERATING CYCLE