Blast Chiller Model AP120BC1000-3 is used to rapidly chill cooked foods to temperatures suitable
for refrigerated storage. It is capable of lowering the core temperature of most foods from 160o F to
40o F in 90 minutes. Chiller/Freezer AP120BCF1300-3 has the same chilling capabilities as the
Blast Chiller and, when the shock freezing option is selected, is capable of lowering the core
temperature of most foods from 160o F to 0o F in 4 hours. Food is loaded into 12" x 20" x 2-1/2"
pans. AP120 models are sized to accept three racks containing up to 120 pans total. All models
can have as options: UV sterilization, an integral temperature recording device (printer) and 2, 3 or
4 food probes instead of one. All models employ a high velocity flow of cooled air to assure even
cooling of the food product, and to quickly bring the food temperature through the danger zone in
which bacteria multiply rapidly. This is done in accordance with the requirements of HACCP, FDA
and all applicable state regulations.

CONTROLLER FEATURES

The electronic control system is solid state and is based on the latest microprocessor technology.
The display is VFD Industrial Type. It displays (4) lines of 20 characters each and allows operator
viewing from any angle. The display is programmed to show clear step-by-step instructions and
operating data. It is capable of storing 250 sets of data and 150 recipes. The unit has built-in
safety and self-diagnostic systems. The controller notifies the operator if various faults, as listed
below, should occur:
¾ Power supply failure / Restoration of power
¾ Faulty air temperature probe
¾ Faulty food temperature probe
¾ High air temperature (above 140o F)
¾ Low air temperature (below -35o F)
¾ High food temperature (above 180o F)
¾ Low food temperature (below 35o F)
As an option, the unit can be operated by a PC. The PC interface allows the operator to remotely
program the unit, operate it, download the data and print the data.

OPERATING MODES

The operator can choose from the following modes:
AUTOMATIC MODE
This is the preferred mode, in which all the food probes are active and take part in controlling the
chilling or freezing process. The cycle will never proceed to its next step until all the probes have
reached their set breaking temperatures. The operator needs only to select the recipe number of
the food to be controlled by each probe (up to 150 recipes can be programmed), then insert each
probe into its food. It is recommended that the operator remove the food when its temperature
starts to flash and the display shows “Ready”. The unit will automatically switch into holding mode
(cavity air temperature between 35o F and 42o F) when all the food have reached the end cycle
programmed temperature.