AP120BC1000-3/ AP120BCF1300-3 Manual

7

INSTALLATION

WARNINGS

READ ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE YOU ATTEMPT TO INSTALL
THE EQUIPMENT.
ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE PERFORMING
ANY SERVICE OR MAINTENANCE.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY
APPROVED & AUTHORIZED BY AMERICAN PANEL CORPORATION. DOING OTHERWISE
MAY VOID THE WARRANTY.
Note: Any changes made to the equipment without authorization from the factory will void
the warranty.

PREPARATION

Check the integrity of the unit once it is unpacked.
Check that the available power supply corresponds to the ratings on the unit's nameplates and that
correctly rated electrical protection is provided.
Quick disconnect must be provided for this unit by the installer.
If additional refrigerant should be needed, be certain to use the correct type.
Make certain that adequate drainage is provided;
Be certain that the remote condensing unit is positioned within the range indicated on page 8
(CONNECTION TO THE REMOTE UNIT) in this manual and that it is connected as specified and
in accordance with all applicable electrical codes.

INSTALLATION

ALL MODELS HAVE REMOTE CONDENSING UNITS. The condensing unit and the cabinet must
be connected and installed in accordance with the following instructions:

LOCATION

Ambient air temperature for air cooled condensing units should be no greater than 90oF to ensure
the rated performance. A remote condensing unit must be located away from direct sunlight if
installed outdoors, or, if it is indoors, a water cooled condensing unit should be used.

DIMENSIONS

MODEL LEFT - RIGHT FRONT - BACK FRONT – BACK
W/ RAMP HEIGHT FRONT-BACK
W/ OPEN DOOR(S)
AP120BC1000-3 (1 door) 59-3/8” 156-3/4” 166” 92-7/8” 190-1/4”
AP120BCF1300-3 (1 door) 59-3/8” 156-3/4” 166” 92-7/8” 190-1/4”
AP120BC1000-3 (2 doors) 59-3/8” 162-3/4” 182-1/8” 92-7/8” 230-1/2”
AP120BCF1300-3 (2 doors) 59-3/8” 162-3/4” 182-1/8” 92-7/8” 230-1/2”