Configuration and Installation
FIG. 8 shows the AXlink/RS-232, DB-9, and power supply wiring diagram. For some applications, you may need to strap pins 7 (request to send) and 8 (clear to send) together depending on the PC (as shown in the illustration).
12 VDC PWR connector | PWR (+) |
on | GND |
| PWR(+) |
AXlink/RS232 connector | AXP/TX |
on | AXM/RX |
| GND |
12 VDC power supply
2 (RXD)
3 (TXD)
5 (GND)
FIG. 8 AXlink/RS-232, DB-9, and power supply wiring diagram
Using the AXlink-to-DB-25 connector cable for a PC system
The
DB-25 Wiring Pinouts
Pin | Signal | Function | Pin | Signal | Function |
|
|
|
|
|
|
1 | N/A | Not used | 6 | DSR | Data set ready |
|
|
|
|
|
|
2 | TXD | Transmit data | 7 | GND | Signal ground |
|
|
|
|
|
|
3 | RXD | Receive data | N/A | Not used | |
|
|
|
|
|
|
4 | RTS | Ready to send | 20 | DTR | Data terminal ready |
|
|
|
|
|
|
5 | CTS | Clear to send | N/A | Not used | |
|
|
|
|
|
|
FIG. 9 shows the AXlink/RS-232, DB-25, and power supply wiring diagram. For some applications, you may need to strap pin 4 (ready to send) to 5 (clear to send) and/or pin 6 (data set ready) to 20 (data terminal ready) depending on the PC.
12 VDC PWR connector | PWR (+) |
on | GND |
PWR(+)
AXlink/RS232 connector AXP/TX on
GND
12 VDC power supply
2 (TXD)
3 (RXD)
7 (GND)
FIG. 9 AXlink/RS-232, DB-25, and power supply wiring diagram
| 8 | |
|
|
|