Terminal (Program Port/Telnet) Commands
111
NI Series WebConsole & Programming Guide
Access Rights Menu

The Access Rights Menu is accessed whenever you select Change Access Rights (option 6) from the

Edit User menu, or Change Access Rights from the Edit Group menu. The options in this menu is

described below:

Adding a Group
1. Type 7 and <Enter> at the Security Setup prompt (at the bottom of the Main Security Menu) to add

a group account. A sample session response is:

The following groups are currently enrolled:
administrator
Enter name of new group:
2. Enter a name for the group. A group name is a valid character string (4 - 20 alpha-numeric

characters) defining the group. This string is case sensitive, and each group name must be unique.

3. Press <Enter> to display the Edit Group menu.

Access Rights Menu

Command Description
1) Terminal (RS232) Access
(Enable/Disable)
Enables/disables Terminal (RS232 Program port) Access. The
account has sufficient access rights to login to a Terminal session
if this option is enabled.
2) Admin Change Password Access
(Enable/Disable)
Enables/disables Administrator Change Password Access. The
account has sufficient access rights to change the administrator
password if this option is enabled.
3) FTP Access
(Enable/Disable)
Enables/disables FTP Access. The account has sufficient access
rights to access the NetLinx Master's FTP Server if this option is
enabled.
4) HTTP Access
(Enable/Disable)
This selection enables/disables HTTP (Web Server) Access. The
account has sufficient access rights to browse to the NetLinx
Master with a Web Browser if this option is enabled.
5) Telnet Access
(Enable/Disable)
This selection enables/disables Telnet Access. The account has
sufficient access rights to login to a Telnet session if this option is
enabled.
6) Configuration Access
(Enable/Disable)
This selection enables/disables Configuration Access rights for
the target Master. The account has sufficient access rights to
access the Main Security Menu if this option is enabled.
5) ICSP Security
(Enabled/Disabled)
This selection enables/disables ICSP communication access.
The account has sufficient access rights to initiate ICSP data
communication.
6) ICSP Encryption Required
(Enabled/Disabled)
This selection enables/disables the need to require encryption of
the ICSP communicated data.
If enabled:
- All communicating AMX components must authenticate with
a valid username and password before beginning
communication with the Master.
- All communication must be encrypted.