Using the NetLinx Module to Program the ViewStat
54 ViewStat Communicating Thermostat
String Feedback (Cont.)
String Description
'T-<tstat> HUMIDIFY-val>' Reports current humidify set point.
Parameters:
<tstat> : id of thermostat/zone
<val> : 0-97 = humidify point (in percent)
Example:
'T-6 HUMIDIFY-30'
'T-<stat> ID-<val>' Reports identification number of thermostat.
'T-<tstat> LOCK-<val>' Reports current thermostat lock state.
Parameters:
• <tstat> : id of thermostat/zone
• <val> :
ON = thermostat is locked
OFF = thermostat is unlocked
Example:
'T-2 LOCK-ON'
'T-<stat> MENU-<val>' Reports Menu state, ON/OFF.
'T-<tstat> MODE-<val>' Reports current HVAC mode.
Parameters:
• <tstat> : id of thermostat/zone
• <val> :
OFF = disabled (no cool, no heat)
HEAT = heat mode (no cool)
COOL = cool mode (no heat)
AUTO = thermostat automatically controls heat and cool
based on set points.
Example:
'T-6 MODE-AUTO'
'T-<tstat> OUTHUM-<val>' Query for current outside humidity.
Parameters:
• <tstat> : id of thermostat/zone
• <val> : 0..100 = humidity level (%)
Example:
'T-8 OUTHUM-68'
'T-<tstat> OUTTEMP-<val>' Reports current outside temperature.
Parameters:
• <tstat> : id of thermostat/zone
• <val> : current outside temperature
Example:
'T-2 OUTTEMP-84'
'T-<stat> PMES<num>-<val>' Reports scrolling message.
Parameters:
• <num>: message 1-4
• <val>: data that message happens to be