Power Threshold. The amount of power used by a device in Sleep or Standby mode varies between devices. It may be necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down.

1.Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it OFF.

2.Press STATUS and hold for three seconds.

3.The G50 unit will display now recognize the threshold level of the Master device and save it as the new threshold setting. Use the UP or DOWN arrow key to adjust the power threshold.

POWER THRESHOLD: 10 W

TRACKING POWER

SUCCESSFULLY

Green Function. Use the Up and Down arrow buttons to enable or disable the green function. The Green Function allows you to utilize the MASTER and CONTROLLED outlets. When the device plugged into the MASTER outlet goes into Sleep or Standby mode, or turns off, the equipment that is connected to the CONTROLLED outlets will also turn off, saving electricity.

GREEN FUNCTIONS

DISABLE

Utility Rate. Enter electrical power utility rate in cents/kWh (USD only). The G50B-20A2 unit will use this to calculate the savings accumulated when using the green function MASTER and Controlled outlets.

UTILITY RATE 12 cents/kWh

Contact Information. This screen can be customized to include the contact information of the A/V dealer or installer. Push the STATUS button to move the cursor to the next letter and use the Up and Down arrow buttons to scroll to the appropriate letter.

1-888-8827228

WWW.APCAV.COM

Maximum and Minimum Voltages. Set the voltage range in which the unit should normally operate. The unit will protect connected equipment from high and low voltages that are not safe for operation.

MAX UPPER VOLT: 140V (132-140)

MIN LOWER VOLT: 92V (92-100)

Clear Saved Power. Reset the counter for the amount of power saved that has been saved by the unit.

CLEAR SAVED PWR

YES

APC A/V G-Type Rack Power Filter: Operation

9

Page 13
Image 13
APC G50B-20A2 manual Power Threshold 10 W Tracking Power Successfully