APW Wyott M Series Location, M-83 & M-95 Toaster, M-91 Toaster, Main S witch - main power On/off

Models: AT/BT Series M Series

1 20
Download 20 pages 40.26 Kb
Page 6
Image 6
LOCATION

LOCATION

.

1.Place the toaster on a flat surface and in such a way that the unit's vents are not blocked. Air must circulate under and through the vents provided on the base, right side (M-83, M83D, & M-95), left side (M-91) and rear of the unit.

2.Locate the unit near a wall receptacle of the proper configuration. DO NOT USE AN EXTENSION CORD. Plug the power supply cord into an outlet (receptacle) of the voltage specified on the unit's

rating plate. Outlets must be properly grounded.

M-83 & M-95 Toaster

Motor Switch

Pilot Light

Temperature

Control

M-83 & M-95 ToasterMain Switch

M-91 Toaster

Motor Switch

Pilot Light

Temperature

Control

Main Switch

M-83 & M-91 OPERATING INSTRUCTIONS

A.PREPARATION

1.Warm-up Time: Turn the control knob to 400°F (number 8) or 450°F (number 9) using optional Teflon Sheet. Wait 15-25 minutes or until the pilot light cycles on and off twice.

2.Use of Oil: Any high-quality oil may be used in the Bun Grill Toaster. While health concerns have led to the decreased use of tropical cooking oils, coconut oil does caramelize when toasted to give the product an appetizing golden color. It also helps the product to reach and maintain the optimum serving temperature. Whereas some cooking oils tend to gum up, those designed for use in toasters will work throughout the day without the need to stop and clean the grill.

B.CONTROL PANEL

The face of the panel has two (2) Iighted rocker switches and a temperature control:

1.Main S witch - main power On/off.

2.Motor Switch - On/off switch turns both butter roller and conveyor on and off.

3.Temperature Control - Controls the temperature of the grill. The pilot light will stay on until the grill temperature has been attained and will then turn off. Allow .the pilot light to cycle twice so the unit is at stabilized temperature for toasting buns.

NOTE: During slow periods to conserve energy and prolong motor life, you may turn temperature control down to 150°F (66°C) and turn off motor switch.

4.Pilot Light - Glows when grill is on.

6

Page 6
Image 6
APW Wyott M Series, AT/BT Series manual Location, M-83 & M-95 Toaster, M-91 Toaster, M-83 & M-91 OPERATING INSTRUCTIONS