INSTALLATION INSTRUCTIONS
CONTINUOUS WATERFALL (INFINITY I):
The Infinity I is equipped with a continuous waterfall that is powered by a recirculation pump. The recirculation pump is plugged into your maintenance heater (see Diagram 4A, pg. 14). The maintenance heater must be plugged in for the continuous waterfall to be operational (see Diagram 4A, page 14). See page 16 for operation instructions.
ELECTRICAL INSTALLATION:
WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES.
WARNING: WHEN USING ELECTRICAL PRODUCTS, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
DANGER: RISK OF ELECTRIC SHOCK!
GFCI’s are not supplied, however we do specify their use.
All known code authorities require GFCI’s.
The Infinity I - VIII will need to be hard wired to the outlets provided. See the following directions and diagram.
Two junction boxes will be mounted to the frame of the whirlpool. One of the two boxes will have one outlet and will be labeled “Blower”. Remove the cover and connect a 14/2 with ground Romex wire from a 15 amp
The second junction box will have two outlets, one labeled “Main” and the other labeled “Heater”. Remove the cover. Run Romex 14/3 with ground from a 15 amp