Heater On Indicator Set Point Indicator

OPERATION of

INFINITY SERIES WHIRLPOOLS

NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD BE 2" ABOVE HIGHEST JET.

BATHSIDE CONTROL SYSTEMS:

INFINITY ON/OFF WITH HEATER CONTROL (SEE DIAGRAM 6A):

1.To Turn Pump On: Pressing the On/Off button will turn the pump on. Pressing a second time will turn the pump off. A built-in timer will turn the pump and heater off after 20 minutes.

2.To Change Temperature: The heater and buttons are used to set water temperature. When pressed, the display shows the actual set point. By pressing up or down, the set point can be changed. Keeping the buttons pressed changes the setting continuously. The temperature can vary from 90° to 104° F.

Note: The set point light (sp) is “On” when the display shows the set point and “Off” when it shows the actual water temperature. The heater’s LED will blink when the system calls for heat and will stay on when the heater is “On”. The control turns the heater “On” when the temperature reaches the set point —1° F and keeps it on until it reaches the set point +1° F.

3.For Infinity I: To Turn Continuous Waterfall On: Pressing and holding down the chromatherapy button for 2 seconds will turn the continuous waterfall on. Depressing the chromatherapy button for 2 seconds with the continuous waterfall on will turn off the

waterfall. However, the light output will automatically turn off after 2 hours; the continuous waterfall will automatically turn off after 20 minutes. Note: The continuous waterfall is only featured on the Infinity I.

Other Features:

• When power is on, the control displays “000” for five seconds and then blanks itself.

• When the pump is shut off, the display shows the water temperature for a period of 15 minutes.

• The High-Limit circuit will shut the heater off if the

6A

 

temperature of the water at the High-Limit sensor

 

reaches 119° F. Should this occur, the display will

 

show “• • • ” but the pump will still be allowed to work. Only the heater will be shut off. In order for the heater to be reactivated the user must reset circuit breaker when the temperature has fallen below 119° F.

When the pump is on, the display will normally show the current water temperature reading and the remaining minutes on the timer. This will toggle every 5 seconds.

16

AQUATIC INDUSTRIES, INC.

Page 15
Image 15
Aquatic Infinity Series Whirlpools, Bathside Control Systems, Infinity ON/OFF with Heater Control see Diagram 6A