INSTALLATION INSTRUCTIONS

ELECTRICAL INSTALLATION (continued):

BREAKER PANEL

15AMP 2 POLE GFCI BREAKER

15AMP 1 POLE

GFCI BREAKER

HEATER

MAIN

RED

 

WHITE

 

BLACK

 

GROUND

 

WHITE

 

BLACK

 

GROUND

 

BLOWER

PLEASE SEE DIAGRAMS 4A AND 4B. (PAGE 14)

BONDING WIRE: Connect a #8 bare copper bonding wire from the pump motor to the heater and then to the cold water plumbing or other suitable ground. Grounding is required.