PTO Switch

Off

Run

Start

 

 

 

 

 

 

 

 

Brown

 

 

11.50-13.00 Volts

 

 

 

 

Purple

 

11.50-13.00 Volts

11.50-13.00 Volts

 

 

 

 

Red/Green

 

11.50-13.00 Volts

11.50-13.00 Volts

 

 

 

 

Brown/Yellow

 

 

11.50-13.00 Volts

 

 

 

 

2 sets of contacts, one normally open, one normally closed. Contact resistance is 0.1-0.3 ohms when correct.

Neutral Switch

Off

Run

Start

 

 

 

 

 

 

 

 

Brown/Yellow

 

 

11.50-13.00 Volts

 

 

 

 

Red/Green

 

11.50-13.00 Volts

11.50-13.00 Volts

 

 

 

 

Normally open contacts manually activated. Contact

Resistance is 0.1-0.3 ohms when correct.

 

PTO Relay

Off

Run

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

Green/White

 

86

 

11.50-13.00 Volts(A)

11.50-13.00

Volts(A)

 

 

 

 

 

 

Black/White

 

85

 

Connected to ground when start relay

 

 

 

 

energized

 

 

 

 

 

 

 

 

 

Purple/White

 

87

 

11.50-13.00 Volts

11.50-13.00

Volts

 

 

 

 

 

 

 

 

 

87A

 

Not Used

Not Used

 

 

 

 

 

 

 

 

Purple

 

30

 

11.50-13.00 Volts

11.50-13.00

Volts

 

 

 

 

 

 

 

Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally open. Contact resistance is 0.1-0.3 ohms when correct.

(A) When PTO switch is on.

Start Relay

 

Off

 

Run

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red/Yellow

86

 

 

11.50-13.00 Volts(A)

 

11.50-13.00 Volts(A)

 

 

 

 

 

 

 

Black

85

 

 

Connected to Ground

 

 

 

 

 

 

 

 

Black/White

87

 

 

 

 

 

 

 

 

 

 

 

 

White/Black

87A

 

Connected to Ignition Module

 

 

 

 

 

 

 

Black

30

 

 

Connected to Ground

 

 

 

 

 

 

 

 

Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally closed. Contact resistance is 0.1-0.3 ohms when correct.

(A) With neutral switch engaged and PTO switch off.

11 - 38