BIOS SPECIFICATION
6-11
THRM Throttle On
Threshold 95 CPU THRM_ON
THRM Throttle Off
Threshold 90 CPU THRM_OFF
Fan Failure Temp Point 65 CPU FANERR
Fan Stop Threshold 50 CPU FSP
STEP T rip Point 1 55 CPU TS1
STEP T rip Point 2 60 CPU TS2
STEP T rip Point 3 65 CPU TS3
STEP T rip Point 4 70 CPU TS4
STEP T rip Point 5 75 CPU TS5
STEP T rip Point 6 80 CPU TS6
STEP T rip Point 7 85 CPU TS7
STEP T rip Point 8 90 CPU TS8
Fan Full Run Threshold 95 CPU FFP
STEP Trip Pointer 1
Hysteresis Offset 3 CPU HYS1
STEP Trip Pointer 2
Hysteresis Offset 3 CPU HYS2
STEP Trip Pointer 3
Hysteresis Offset 3 CPU HYS3
STEP Trip Pointer 4
Hysteresis Offset 3 CPU HYS4
STEP Trip Pointer 5
Hysteresis Offset 3 CPU HYS5
STEP Trip Pointer 6
Hysteresis Offset 3 CPU HYS6
STEP Trip Pointer 7
Hysteresis Offset 3 CPU HYS7
STEP Trip Pointer 8
Hysteresis Offset 3 CPU HYS8
STEP Trip Pointer 1 Duty 73 CPU DA1
STEP Trip Pointer 2 Duty 95 CPU DA2
STEP Trip Pointer 3 Duty 117 CPU DA3
STEP Trip Poin ter 4 Duty 139 CPU DA4
STEP Trip Poin ter 5 Duty 161 CPU DA5
STEP Trip Poin ter 6 Duty 183 CPU DA6
STEP Trip Poin ter 7 Duty 205 CPU DA7
STEP Trip Poin ter 8 Duty 227 CPU DA8
Rising Limi t Range 1 6 CPU Addscl1
Rising Limi t Range 2 12 CPU Addscl 2
Rising Limi t Range 3 22 CPU Addscl 3
Rising Limi t Range 4 24 CPU Addscl 4
Rising Limit Value 1 1 CPU AddDA1
Rising Limit Value 2 2 CPU AddDA1
Rising Limit Value 3 4 CPU AddDA1
Rising Limit Value 4 6 CPU AddDA1
Falling Limit Range 1 6 CPU Decscl1
Falling Limit Range 2 12 CPU Decscl2
Falling Limit Range 3 22 CPU Decscl3
Falling Limit Range 4 24 CPU Decscl4
Falling Limit Value 1 1 CPU DecDA1
Falling Limit Value 2 2 CPU DecDA2
Falling Limit Value 3 4 CPU DecDA3
Falling Limit Value 4 6 CPU DecDA4