KH1508i / KH1516i User Manual

Fill in the required information for a new profile, or modify the existing information to edit a previous profile. A description of the field headings is given in the table below:

Heading

Description

 

 

Username

A minimum of 6 and a maximum of 16 characters is allowed.

 

 

Password

A minimum of 8 and a maximum of 16 characters is allowed.

 

 

Confirm Password

To be sure there is no mistake in the password, you are asked

 

to enter it again. The two entries must match.

 

 

Description

Additional information about the user that you may wish to

 

include.

 

 

Admin

Enabling this gives the user Administrator level access to the

 

KH1508i / KH1516i. All permissions are granted. (See

 

Permissions, in this table.)

 

 

User

Enabling this gives the user User level access to the KH1508i /

 

KH1516i. Windows Client, Power Manager, and Java Client

 

permissions are granted. (See Permissions, in this table.)

 

 

Select

This button is automatically enabled if the permission choices

 

selected by the Administrator (in the panel just below) do not

 

match the default access level choices for Admin or User.

 

 

Permissions

These are used together with the Select radio button to set up

 

permissions that differ from the defaults for Admin and User.

 

1. Checking Administration gives a User administration privi-

 

leges, which allows him to set up and modify the KH1508i /

 

KH1516i's Administration page settings.

 

2. Checking Windows Client allows a user to access the

 

KH1508i / KH1516i via the Windows Client software. By

 

default, all users may access the KH1508i / KH1516i via the

 

Windows Client software.

 

3. Checking Log allows a User to view and query the log file.

 

The Log and Log Server buttons appear on the Main web

 

page of Users who have Log permission (see the

 

screenshot on page 52).

 

4. Checking Power Manager allows a User to connect to

 

Power on the Net™ devices. The PON button appears on

 

the Main web page of Users who have Power Manager

 

permission (see the screenshot on page 52).

 

5. Checking Java client allows a User to access the KH1508i /

 

KH1516i via the Java Client software.

 

 

(Continues on next page.)

66