KL1508A / KL1516A User Manual

Administrator Login Failure

If you are unable to perform an Administrator login (because the Username and Password information has become corrupted or you have forgotten it, for example) you can clear the login information with the following procedure:

1.Power off the KL1508A / KL1516A and remove its housing.

2.Short the jumper labeled J15.

J15

3.Power on the switch.

The on screen display will show a message informing you that the password information has been cleared.

4.Power off the switch.

5.Remove the jumper cap from J15.

6.Close the housing and start the KL1508A / KL1516A back up.

After you start back up, you can use the default Username and Password (see OSD Overview, page 33) to log in.

76