2.2.2 PRE-CAST FLUE OF MINIMUM SIZE (Fig. 2)
This fire can be installed into a properly constructed
NOTES:
1.The minimum dimensions for the flat area around the opening are 686 mm high x 635 mm wide.
2.The flue spigot restrictor MUST NOT be fitted.
Ensure that any mortar fangs between the blocks do not protrude into the flueways and if raking blocks are used they are fitted according to the manufacturers instructions and mortar is not allowed to drop down and accumulate in the raked portions.
CHECK THE FLUE FOR GOOD DRAUGHT AS DETAILED IN SECTION 2.2.1.