INSTALLATION REQUIREMENTS/SPECIFICATIONS

2.3EPIM SPECIFICATIONS

EPIMs let you connect the SEHI to the main network using different media types. Cabletron Systems offers a variety of EPIMs. The following sections explain specifications for each EPIM.

2.3.1EPIM-T

The EPIM-T is an RJ45 connector supporting UTP cabling. It has an internal Cabletron Systems TPT-T™ 10BASE-T Twisted Pair Transceiver.

The slide switch on the EPIM-T determines the cross-over status of the cable pairs. If the switch is on the X side, the pairs are internally crossed over. If the switch is on the = side, the pairs are not internally crossed over. Figure 2-3 shows the pinouts for the EPIM-T in both cross-over positions.

Position X (crossed over)

1. RX+

5. NC

2. RX-

6. TX-

3. TX+

7. NC

4. NC

8. NC

 

 

Position = (not crossed over)

1. TX+

5.

NC

2. TX-

6.

RX-

3. RX+

7. NC

4. NC

8. NC

Figure 2-3. EPIM-T Pinouts