INSTALLATION

If you disconnect one end of a HubSTACK Interconnect cable and leave the other end attached to the hub, ensure that you disconnect the cable from the OUT port as shown in Figure 3-2. This ensures that the HubSTACK Interconnect cable is terminated properly.

Disconnect SEH and SEHI Interconnect Cables

at the "OUT" Port.

SEH-2410BASE-T HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEH-2410BASE-T HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEHI-2410BASE-T HUB WITH LANVIEW®

SEH INTERCONNECT

OUT

Figure 3-2. Disconnecting the HubSTACK Interconnect Cable

3.2.2Attaching the Strain Relief Bracket

Attach the strain relief bracket to the front of the SEHI as follows:

1.Locate the strain relief bracket and four 8-32 x 3/8" screws from the SEHI-ACCY-KIT package.

Warning: Use of longer screws may cause damage to the unit or electrical shock.

2.Attach the strain relief bracket to the bottom of the SEHI as shown in Figure 3-3.

HubSTACK 10BASE-T HUB WITH LANVIEW®

SEHI-24

Figure 3-3. Attaching the Strain Relief