TROUBLESHOOTING

2.If the remote station is ready and the LNK LED is on, but no data passes through the port, one of two conditions may exist:

Network management has disabled the port.

The port is segmented either because the collision detector was on for more than 110 ∝sec. or the SEHI detected more than 32 consecutive collisions on the attached segment. The affected port remains segmented until a good packet is transmitted/ received without collisions.

If the LNK LED is still not on, contact Cabletron Systems Technical Support.

5.2USING LANVIEW

The SEHI incorporates the Cabletron Systems LANVIEW Status Monitoring and Diagnostics System. LANVIEW LEDs can help diagnose problems such as a power failure or a cable fault. The SEHI includes the following LANVIEW LEDs:

PWR, for power status

CPU, for board status

RCV (Receive), LNK (Link), and CLN (Collision) for Ethernet status.

Figure 5-1 provides a quick reference chart of LED locations and definitions. This chapter also includes a detailed description of each LED.

Page 5-2

Page 55
Image 55
Cabletron Systems SEHI-34, SEHI-22, SEHI-32, SEHI-24 manual Using Lanview