INSTALLATION REQUIREMENTS/SPECIFICATIONS

2.1.6AUI Cable Requirements for the EPIM-A and EPIM-X Modules

When you connect an external network segment to the SEHI (via an EPIM-A or EPIM-X), the AUI cable must meet the following requirements:

AUI Cable

The AUI cable connecting the module to a device must be IEEE 802.3 type cable.

Length

The AUI Cable must not exceed 50 meters in length. If 28 AWG thin office drop AUI cable is used, then the maximum cable length is limited to 50 feet (15.24 meters).

Grounding

The connector shell of the EPIM-A and the EPIM-X are connected to ground.

2.2NETWORK PORT SPECIFICATIONS

The SEHI-22 and SEHI-24 network ports are shielded RJ45 connectors that support both STP and UTP cabling. The SEHI-32 and SEHI-34 provide a 50 pin Champ style connector for network connections. The following sections provide specifications for each SEHI model.

Page 2-7

Page 21
Image 21
Cabletron Systems SEHI-32, SEHI-22 AUI Cable Requirements for the EPIM-A and EPIM-X Modules, Network Port Specifications