ATTO Technology S-Class manual Type set QuickRAID5 1 Type SaveConfiguration Restart

Models: S-Class

1 105
Download 105 pages 63.96 Kb
Page 71
Image 71

2Type set QuickRAID5 1 1

3Type SaveConfiguration Restart

The array is configured into one RAID Level 5 group with one Hot Spare sled.

To set up two RAID Level 5 groups with two Hot Spare sleds

1Connect to Diamond Storage Array services (refer to Accessing the Array on page 17) and use

the CLI or enter ATTO ExpressNAV browser interface Advanced CLI Configuration page.

2Type set QuickRAID5 2 2

3Type SaveConfiguration Restart

The array is configured into two RAID Level 5 groups with two Hot Spare sleds. Refer to Exhibit 6.4-1

Exhibit 6.4-1 LUNs are set up using the drives and sleds shown here. Parity information is spread throughout each LUN.

 

Sled

1

 

2

 

3

 

 

4

 

 

5

 

 

 

6

 

 

 

 

 

7

 

 

 

8

 

9

 

 

 

 

 

10

 

 

 

11

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

1

 

2

1

 

2

1

 

 

2

 

1

 

2

1

 

2

 

1

 

2

 

1

 

 

 

2

1

 

 

2

 

1

 

2

 

1

 

 

2

 

 

1

 

2

 

1

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QuickRAID5 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUN 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QuickRAID5 2

 

 

 

 

 

 

 

 

 

 

LUN 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUN 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QuickRAID5 3

 

 

 

 

 

LUN 1

 

 

 

 

 

 

 

 

 

 

 

 

LUN 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUN 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QuickRAID5 4

 

 

 

LUN 1

 

 

 

 

 

 

 

 

 

 

LUN 2

 

 

 

 

 

 

 

 

 

 

 

LUN 3

 

 

 

 

 

 

 

 

 

LUN 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhibit 6.4-2 Drives are striped, and parity information is interspersed among the sleds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical Sled

1

 

 

2

 

 

3

 

4

 

5

 

 

 

 

6

 

 

7

 

8

 

 

 

 

9

 

 

 

10

11

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical Drive

1

 

 

2

1

2

1

2

 

1

 

2

1

2

1

 

 

2

1

 

2

1

2

 

1

2

 

1

 

2

1

2

1

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 1

Virtual Drive

 

1

 

2

 

 

3

 

4

 

5

 

 

 

 

6

 

 

7

8

 

 

 

 

9

 

 

10

11

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 2

 

Striping

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 3

Created LUN

 

 

 

 

 

 

LUN 1

 

 

 

 

 

 

LUN 2

 

 

 

 

 

 

 

 

 

 

 

LUN 3

 

 

 

 

 

 

 

LUN 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhibit 6.4-3 Configuration of sleds in RAID Level 5 in a fully populated array (12 sleds).

Sled

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QuickRAID5 1 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUN 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spare

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QuickRAID5 2 2

 

 

 

 

 

 

LUN 1

 

 

 

 

 

 

 

 

 

 

 

 

LUN 2

 

 

 

 

 

 

Hot

Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spare

Spare

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 RAID Level 5

Page 71
Image 71
ATTO Technology S-Class manual Type set QuickRAID5 1 Type SaveConfiguration Restart

S-Class specifications

ATTO Technology S-Class is a comprehensive solution designed to optimize storage and networking performance for digital content creation and enterprise environments. This product line specializes in high-performance connectivity, facilitating seamless data transfer and management.

One of the key features of the S-Class is its advanced RAID (Redundant Array of Independent Disks) capabilities. This incorporates various levels of RAID configurations, enabling users to choose the right balance between performance and redundancy. The technology ensures data integrity while maximizing throughput, a crucial aspect for workflows dealing with large files such as video editing and graphic design.

Another standout characteristic of the S-Class is its support for high-speed interfaces, including Thunderbolt and Fibre Channel. With the ability to leverage these high-bandwidth connections, users can achieve exceptional data transfer rates that significantly reduce the time required for file uploads and transfers. This is particularly important in environments demanding real-time data access, such as broadcasting and production studios.

The S-Class also incorporates intelligent storage management features. The ATTO ConfigTool offers a user-friendly interface for monitoring and configuring storage settings, allowing for real-time adjustments and performance tuning. This ensures that users can effectively manage their storage resources, balancing capacity and performance according to their specific needs.

Furthermore, the technology employs a robust set of data protection mechanisms, including snapshot and backup capabilities. This ensures that critical data is safeguarded against potential loss, enhancing operational reliability. The integration of these features supports comprehensive workflow solutions, benefiting industries that require continuous access to high-volume data.

Lastly, the S-Class is built to integrate seamlessly with popular operating systems and platforms, providing versatility and ease of deployment. Whether used in a small studio or a large enterprise environment, ATTO Technology's S-Class stands out as a solution that combines speed, reliability, and manageable performance, making it a top choice for professionals who demand the best in their storage and network infrastructure.

In summary, ATTO Technology S-Class is not just a storage solution; it's a gateway to unlocking peak performance in data management, tailored for the challenges of today’s data-driven landscape.