You must use a SaveConfiguration Restart command to implement the rebuild priority command.

To synchronize mirrored drives manually

1Connect to Diamond Storage Array services via the RS-232 port or the optional Ethernet management services card (refer to Accessing the Array on page 17). You should now be in CLI.

2Continue with the CLI or access the RAID page of the ExpressNAV interface (refer to ATTO ExpressNAV: Browser-based Interface on page 25).

3 If AutoRebuild has not been disabled, type

set AutoRebuild disabled saveconfiguration restart.

4After the array reboots and completes its diagnostics, enter the CLI and type RAIDManualRebuild L S where L is the LUN and S is the sled to be rebuilt.

This procedure may take a few hours, depending on the size of the LUN.

5To check the rebuild status, type

RAIDRebuildStatus

66

Page 77
Image 77
ATTO Technology S-Class To synchronize mirrored drives manually, Set AutoRebuild disabled saveconfiguration restart