ATTO Technology S-Class manual Cd c\diamond\flash, Type put ....ima

Models: S-Class

1 105
Download 105 pages 63.96 Kb
Page 89
Image 89

4Copy the latest Diamond Storage Array image file (“...”.ima) onto the host computer and note its directory

c:\diamond\flash\“...”.ima

5Change directories to the place where you copied the “...”.ima file

cd c:\diamond\flash

6Open an FTP session using a user-defined IP address or the default (10.0.0.1) if it has not changed. The IP address must be a valid address for your network.

7At the FTP login prompt, type sysadmin as the userID.

8Press return at the password prompt.

9Type put “...”.ima.

The Diamond should acknowledge receiving the file and display a message not to interrupt power for 90 seconds.

CAUTION

Do not interrupt the flash process. If the process is interrupted, the Diamond Storage Array will become inoperable and will have to be returned to the factory for repair.

Do not turn off the Diamond Storage Array until the display returns the Ready prompt.

10If upgrading the firmware from versions older than 2.5.3, follow the procedures outlined in

Resetting Defaults on page 85.

11When the flash procedure is complete, cycle power on the array.