PROCEDURE FOR 45° ANGLE INSTALLATION

PROCEDURE FOR 45° ANGLE INSTALLATION

NOTE: If the anti-vibration spring position has been changed and verified for 45° angle

1

Set the left and right anti-vibration springs to position

 

"45°".

position "45°"

V

45

H

 

 

45°

3 Determine the mounting location, and drill four mount- ing holes.

Never mount the unit near the fuel tank.

2 Attach bracket (L) and bracket (R) to each side of the unit, using the hexagonal bolts with washer base (M5 x 10).

NOTE: Use seals (A) to cover unused mounting holes on sides of unit.

Bracket (L)

Bracket (R)

Hexagonal bolt

with washer base (M5 x 10)

4 Mount the unit in place, using four self-tapping screws (M5 x 12).

Use RTV (silicone sealer) on screw threads or around the holes to prevent moisture intrusion.

Self-tapping screw (M5 x 12)

Drill holes 4mm in diameter.

Bracket (L)

Bracket (R)