Avalon Stoves 99200149 dimensions ZC Kit - Large Pellet Insert, Compatibility, Packing List

Models: 99200149 ZC Kit

1 8
Download 8 pages 61.11 Kb
Page 1
Image 1
ZC Kit – Large Pellet Insert

 

ZC Kit – Large Pellet Insert

 

(99200149)

Compatibility

Packing List

Astoria Bay Pellet Insert

ZC Can Rear Panel

ZC Can Top/Side Panel

Yankee Bay Pellet Insert

ZC Can Rear Vent Shield

 

(26) # 8 x 3/8” Type A Screws

Overview

This kit allows an installer to build the above pellet heaters into the framing of a home.

Installation Overview

The minimum framing dimensions and clearances listed in this instruction sheet must be maintained. Failure to follow all of the instructions in this instruction sheet, and in the manual, will void the listing and warranty of the pellet heater, and may create a serious fire hazard.

This kit is approved for use in a mobile home.

1Determine the vent configuration (see “Vent Requirements” and “Vent Termination Requirements”)

2Prepare the enclosure (see “Minimum Enclosure Dimensions”).

3Install the floor protection and hearth (see “Minimum Floor Protection”).

If venting to the rear (most common)

Place the 90° onto the insert starter collar and measure the height of the center of the vent. This will determine the center height of the wall thimble installed behind the insert in the wall. NOTE: The vent is located 7.5” left of center of the appliance. Install the thimble into the wall, making sure the 3” clearance to combustibles is met (refer the directions included with the thimble for additional details). Remove the starter collar from the pellet heater and install it onto the elbow (seal with silicone). Determine the correct length for the horizontal section of vent (the center of the starter collar is 11.25” behind the enclosure opening) and attach it to the elbow (seal with silicone). Place this flue section aside until after the zc can is installed. Then insert the flue section through the can and thimble. Once the insert is in place, attach the starter section to the insert (it is attached with a latch – make sure the gasket is correctly positioned). Attach the additional vent components to finalize the vent installation (termination, elbow, etc.).

If venting upwards

When installing with vertical vent, the area above the insert must be accessible after the zc can and insert have been installed (note: the vent is located 11.25” behind the enclosure opening, 7.5” left of center). Remove the starter collar from the pellet heater and install it onto the vent (seal with silicone). Insert this vent through the zc can and attach the starter section to the insert (it is attached with a latch – make sure the gasket is correctly positioned). Attach the additional vent components to finalize the vent installation (additional vent lengths, elbows, terminations, etc.).

3Construct and Install the ZC Can (see “ZC Can Construction and Placement”)

4Prepare the insert in place it into the ZC Can (see “Insert Preparation and Placement”)

Page 1 of 8

10/9/06

© Travis Industries, Inc.