Avalon Stoves Vent Requirements, ZC Kit - Large Pellet Insert, Feet 20 Feet, 0Feet, 5Feet

Models: 99200149 ZC Kit

1 8
Download 8 pages 61.11 Kb
Page 2
Image 2
Vent Requirements

ZC Kit – Large Pellet Insert

(99200149)

Vent Requirements

Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc…) must be sealed with 500° F. RTV silicone.

Pellet vent must maintain a minimum 3" clearance to any combustible (install vent at clearances specified by the vent manufacturer).

Do not connect the pellet vent to a vent serving any other appliance or stove.

The maximum venting distance is shown in the illustration to the right.

Do not install a flue damper in the exhaust venting system of this unit.

 30 Feet 33 Feet (max.)

 25 Feet 30 Feet

Use an approved wall thimble when passing the vent through walls and a ceiling support/fire stop spacer when passing the vent through ceilings (make sure to maintain 3" clearance to any combustibles.

The vent height and run must not exceed the distance shown in the shaded region shown to the right.

0Feet 25 Feet

5Feet 20 Feet

No more than 180° of elbows (two 90° elbows, one 90° and two 45° elbows, etc.).

Pellet vent connections must be sealed airtight with 500° F. RTV silicone and screwed together with at least three sheet metal screws.

 

Seal each vent section (including

.RTV

adapters, elbows, etc...) by

injecting a liberal amount of 500°

F

500

°

 

Silicone

F. RTV silicone into the gap

 

 

between sections.

Vent must have a support bracket every 5' of pellet vent when exterior of structure

Horizontal sections must have a 1/4"

rise every 12" of travel.

Venting into this shaded area may require restrictor adjustments. See the  15 Feet section “Restrictor

Adjustment” for details.

NOTE: To achieve optimum performance, we recommend keeping the vent as short as possible (horizontal run especially).

0Feet

5Feet

Manual background 15 Feet

Manual background 10 Feet

Manual background 5 Feet

Manual background 0 Feet

10 Feet (max.)

Page 2 of 8

10/9/06

© Travis Industries, Inc.

Page 2
Image 2
Avalon Stoves 99200149 dimensions Vent Requirements, ZC Kit - Large Pellet Insert, Feet 20 Feet, 0Feet, 5Feet