Avalon Stoves 99200149 dimensions Minimum Floor Protection, ZC Kit - Large Pellet Insert

Models: 99200149 ZC Kit

1 8
Download 8 pages 61.11 Kb
Page 5
Image 5
Minimum Floor Protection

ZC Kit – Large Pellet Insert

(99200149)

Minimum Floor Protection

The insert must be placed on a non-combustible floor protector (cement board, sheet metal, etc.) a minimum .018” thick (26 gauge). This floor protection must extend the full width and depth of the enclosure and must protrude 6” in front of the door opening (18” from the enclosure opening) and the full width of the surround panels (45” min. width).

HEARTH NOTE: If you wish to install a hearth greater than 1/2” thick, you will need to raise the insert and enclosure height the equivalent amount. The leveling bolts may be used on the insert for adjustments.

Floor

45” Min.

(width of surround panels)

18” Min.

12”

Minimum

Enclosure Height

(measure from top of

floor protection)

Floor Protection

Rear Vent Installations

Place the stove on top of the floor protection and measure the center of the

flue. This will determine the location of the wall thimble.

Page 5 of 8

10/9/06

© Travis Industries, Inc.

Page 5
Image 5
Avalon Stoves 99200149 dimensions Minimum Floor Protection, ZC Kit - Large Pellet Insert