PARTNER® Advanced Communications System
47
Form G2: Instructions for T1 Module Line Settings
Form G2: Instructions for T1 Module Line Settings 0
COLUMN 1 – LINE
Displays the line on the PARTNER system.
COLUMN 2 – T1 CHANNEL NO.
Displays the T1 channel associated with the PARTNER line.
COLUMN 3 – LINE TYPE
Enter whether this line will be used for voice calls. Choices are T1-E&M (Eq uipped) and T1-UNEQ (Unequipped). Use T1-E&M for all T1 lines
that will be used for voice calls using the PARTNER T1 module.
COLUMN 4 – HOLD DISCONNECT TIME
Enter the hold disconnect time for this line. Choices are No detection, or 10 msec to 2400 msec in 10 msec increments.
COLUMN 5 – ASSIGN LINE FOR DID OPERATION
Enter whether this line has Direct Inward Dialing.
COLUMN 6 – INWARD DIAL MODE
The inward dial mode for the T1 line is Touch Tone.
COLUMN 7 – INCOMING SEIZURE TYPE
Enter the type of incoming signaling for this line. Choices are Wink and Automatic. For T1 lines with DID service, use Wink. For T 1 lines without
DID service, use Automatic.
COLUMN 8 – OUTWARD DIAL MODE
The outward dial mode for the T1 line is Touch Tone.
COLUMN 9 – OUTGOING SEIZURE TYPE
Enter the type of outgoing signaling for this line. Choices are Wink and Auto matic. For T1 lines connected to a Central Office, use Wink.
Consult your T1 service provider for more information.
COLUMN 10 – SUPPLY LOCAL DIAL TONE
Enter whether the PARTNER system should provide dial tone when PARTNER users go off hook on this line. Choices are No (the T1 Service
Provider provides dial tone) and Yes (the PARTNER system provides dial tone).
COLUMN 11 – INCOMING ANSWER SUPERVISION TIME
Enter the incoming answer supervision time for this line. Choices are 20 ms ec to 4800 msec in 20 msec increments.