To configure dome protocol, select a camera first and set the communications protocol associated with dome camera using the Direction keys and ENTER. The available protocol includes <DynaColor>, <Pelco D>, <Pelco P>, <AD422>, <Fastrax 2> and <None> (default).

NOTE: The settings become effective after saving the changes and exiting from the menu.

4.6.3RS485 Setup

AVE DR16X / AVE DR8X series controls the domes via RS-485 communication protocol. The RS-485 parameters of AVE DR16X / AVE DR8X series must be set to the same as the parameters set in dome camera .

Users are allowed to change the RS-485 settings of the AVE DR16X / AVE DR8X series. Select <System Setup> in Main menu, then select <RS485 Setup> from the System Setup menu and press ENTER. The following menu is displayed.

 

 

RS485 Setup

1

Unit ID

224

2

Baud Rate

9600

3

Bits

8

4

Stop

1

5

Parity

None

The ID number must match the ID address set by the dome. The Unit ID is in the range of 1 to 255. The default ID is 224. Note that no two devices on the same bus should be given the same ID address, or a conflict may occur.

The default AVE DR16X / AVE DR8X series RS-485 settings are 9600 Baud, 8 Data Bits, 1 Stop Bit and No Parity.