Extending Cable Lengths

Cat-5e cables can be extended by using a simple passive device called an inline coupler to add length to existing cables (as long as you do not exceed the specified maximum cable length). If you need a longer cable on occasion, this is a simple solution. Note that it is possible that the maximum cable length specification can be compromised by using inline couplers or other passive cable connection devices.

For long cable runs (in excess of 500 feet), any Pro16 device can be used to extend the distance between two points. Each Pro16 device refreshes the A-Net signal, allowing another 500 feet of cable to be used.

Cleaning and Maintenance

The exterior of your Aviom products should be cleaned with a dry, soft, lint-free cloth. For tougher dirt, you can use a cloth slightly dampened with water or with a mild detergent.

When cleaning your Aviom products, never spray cleaners directly onto the product surfaces. Instead, spray a small amount of the cleaning solution onto a clean cloth first. Then use the dampened cloth to clean the product.

PNote: Never use solvents or abrasive cleaners on the finished surfaces of your Aviom products.

AC Line Conditioning

Aviom products are digital devices and as such are sensitive to sudden spikes and drops in the AC line voltage. Changes in the line voltage from lightning, power outages, etc., can sometimes damage electronic equipment.

To minimize the chance of damage to your equipment from sudden changes in the AC line voltage, you may want to plug your equipment into a power source that has surge and spike protection. Power outlet strips are available with built-in surge protection circuits that may help protect your equipment.

Other options for protection of your equipment include the use of an AC line conditioner or a battery backup system (sometimes referred to as an uninterruptible power supply, or UPS).

Mounting the AV-P2

The AV-P2 module is designed to be mounted to any flat surface. Optionally, it can be rack mounted using a standard 19-inch rack shelf. Two AV-P2 units can fit on a single rack shelf.

The mounting flanges on each side of the device are designed to support the weight of the AV-P2 without additional hardware. The mounting flanges can be reversed easily using only a Phillips head screwdriver. Each mounting flange contains holes for two screws per side. Always support the unit with all four screws when attaching the product to a flat surface.

If desired, the mounting flanges can be turned around so that they mount under the AV-P2, making the profile of the AV-P2 as small as possible. Always use all the mounting screws when reversing the flanges on the AV-P2.

Always allow adequate ventilation for devices mounted in equipment racks. Avoid placing your AV-P2 directly above or below other rack- mounted devices that produce high levels of heat, such as power amps.