32AXIS 216FD - Event Configuration

 

Object Size

History

Sensitivity

 

 

 

 

High level

Only very large objects

An object that appears in the region will

Ordinary colored objects on ordinary

 

trigger motion detection

trigger the motion detection for a long

backgrounds will trigger the motion

 

 

period

detection

 

 

 

 

Low level

Even very small objects

An object that appears in the region will

Only very bright objects on a dark back-

 

trigger motion detection

trigger motion detection for only a very

ground will trigger motion detection

 

 

short period

 

 

 

 

 

Default value

Low

Medium to High

Medium to High

 

 

 

 

Examples:

Avoid triggering on small objects in the video image by setting the object size level to high.

To reduce the number of triggers if there is a lot of movement during a short period of time, select a high history level.

To only detect flashing light, low sensitivity can be selected. In other cases, a high sensitivity level is recommended.

Port Status

Under Event Configuration > Port Status there is a list showing the status for the camera’s input and output. This is for the benefit of Operators, who have no access to the System Options section.

Example: If the Normal state for a push button connected to an input is set to Open circuit - as long as the but- ton is not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.

Page 32
Image 32
Axis Communications 216FD user manual Port Status, Object Size