AXIS Q1614 Network Camera

Detectors

To control the number of motion detection alarms, the parameters Object Size, History and Sensitivity can be adjusted. See Motion Detection Parameters on page 36.

Once motion detection windows are configured, the Axis product can be configured to perform actions when motion is detected. Possible actions include uploading images and start recording. For more information, see Set Up Action Rules on page 40.

Note

Using the motion detection feature may decrease the product’s overall performance.

The position of the Motion Detection Window is relative to the orientation of the Camera. Changing the orientation of the camera will also change the position of the Motion Detection Window.

Set Up Motion Detection Windows

To set up a motion detection Include Window, follow these instructions:

1.Go to Detectors > Motion Detection.

2.Select the Configure Included Windows option and click New. Select the new window in the list of windows and enter a descriptive name.

3.Adjust the size (drag the bottom right-hand corner) and the position (click on the text at the top and drag to the desired position) of the window.

4.Adjust the Object Size, History and Sensitivity profile sliders (see Motion Detection Parameters for details). Any detected motion within an active window is indicated by red peaks in the Activity window.

5.Click Save.

To exclude parts of the include window, select the Configure Excluded Windows and position the exclude window within the include window.

To delete an include or exclude window, select the window in the list of windows and click Del.

Motion Detection Parameters

The parameters controlling motion detection are described in the table below:

Parameter

Object Size

History

Sensitivity

 

 

 

 

Description

Object size relative to window

Object memory length.

Difference in luminance

 

size.

 

between background and

 

 

 

object.

 

 

 

 

36

Page 36
Image 36
Axis Communications AXIS Q1614 user manual Set Up Motion Detection Windows, Motion Detection Parameters