AXIS Q1931–E PT Mount Thermal Network Camera

Events

-Motion Detection – Trigger the rule when motion is detected. See Motion Detection on page 25.

-Shock Detected – Trigger the rule when the Axis product detects it has been tilted or hit. See Shock Detection on page 25.

Hardware

-Heater – Trigger the rule if the heater is malfunctioning. This can for example be used to send maintenance notifications.

-Network – Trigger the rule if network connection is lost or restored. This can for example be used to start recording to the SD card.

-Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This can for example be used to send maintenance notifications.

Input Signal

-Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See Controls on the Live View Page on page 9 . This can for example be used to validate actions during product installation and configuration.

-Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for example, be connected to buttons in the VMS user interface.

PTZ

-Moving – Trigger the rule when the camera view moves due to a PTZ operation. This can for example be used as an additional condition to prevent an action rule triggered by motion detection to record video while the camera view moves due to a PTZ operation.

-Preset Reached – Trigger the rule when the camera stops at a preset position. This can be for example be used with the Send Images action to upload images from the preset position.

-Ready – Trigger the rule when the PTZ functionality is ready to be used. This can for example be used to steer the camera to a specific preset position when the product is started.

Storage

-Disruption – Trigger the rule if storage problems are detected, for example if the storage device is unavailable, removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance notifications.

-Recording – Triggers the rule when the Axis product records to the storage device. The recording status trigger can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to record to the storage device. Note that, this trigger can be used only for edge storage recording status.

System

-System Ready – Trigger the rule when the product has been started and all services are running. This can for example be used to send a notification when the product restarts.

Time

-Recurrence – Trigger the rule periodically. See Recurrences on page 34. This can for example be used to upload an image every 5 minutes.

-Use Schedule – Trigger the rule according to the selected schedule. See Schedules on page 34.

Actions

Available actions include:

Overlay Text – Display an overlay text. See Use Overlay Text in an Action Rule on page 18.

32

Page 32
Image 32
Axis Communications Q1931E PT user manual Actions