Byte 5

Table 24. Byte 5

 

 

 

 

 

 

 

 

 

 

 

Byte 5

 

 

 

 

 

 

 

 

 

 

 

Bit Function

Bit 7

Bit 6

 

Bit 5

 

Bit 4

 

Bit 3

 

Bit 2

 

Bit 1

Bit 0

 

 

MSGVAL

 

 

 

TXIE

 

RXIE

 

 

INTPND

Sets the message valid

 

1

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the message invalid

 

0

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmit interrupt set

 

 

 

 

 

 

 

1

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmit interrupt not set

 

 

 

 

 

 

 

0

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive interrupt set

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

0

 

 

 

 

 

 

 

Receive not set

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

 

 

 

 

 

Interrupt has occurred

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

0

 

No interrupt pending

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The dark gray (white letters) should be set to this value when sending a new message to the 1939STB.

MSGVAL Bits 6 and 7

Message Valid. The message must be valid before any operations can be preformed on it. Messages can be preloaded on the converter and activated / deactivated as needed. Note that all messages locations are set invalid at power up. Any time the converter is reset, all message information is lost.

TXIE Bits 5 and 4

Transmit Interrupt Enable. Set bit(s) INTPND after a message is successfully sent to the bus.

RXIE Bits 3 and 2

Receive Interrupt Enable. Set bit(s) INTPND after a message is received from the bus. NOTE: It is possible to send a remote frame by setting both the TXIE and RXIE. The controller will clear the TXIE after the message is sent or if the data is received before the message can be sent.

INTPND Bits 1 and 0

Interrupt Pending. Indicates that a message object has generated an interrupt request. Be aware that when a message is being serviced by the controller, it is temporarily inactive. This prevents a message from being overwritten by the J1939 controller while the message is being loaded to the serial port. During the upload the message location cannot receive or transmit.

16

1939STB4600 Manual

 