Message Information

Table 22. J1939 Message Information

Message Information

B

 

B

 

B

B

B

B

B

5

 

6

 

7

8

9

10

11

 

 

95

 

 

E7

 

0C

80

00

40

 

8C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The message information controls the action of the message. It also contains the header information that will be sent out on the J1939 bus. The bytes that control the message and are not transmitted to the bus are grayed in. Byte 5 and 6 are the message control bytes. They work together to control the message. The bit fields are set up in a two bit configuration as follows: NOTE: Byte 11 covered on page 18.

Table 23. Two Bit Values for Byte 5 and 6

Value of 2 bit field

 

Function on write

 

Function on read

0

 

0

 

Reserved

 

Reserved

 

0

 

 

1

 

 

Reset element

 

 

Element is reset

 

 

1

 

 

0

 

 

Set element

 

 

Element is set

 

 

1

 

 

1

 

 

No change

 

 

Reserved

 

The bit values shown in gray are the only values valid for the setup of the 1939STB.

1939STB4600 Manual

15

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445

Page 17
Image 17
B&B Electronics 1939STB manual Message Information J1939 Message Information, Two Bit Values for Byte 5