Bytes 9 and 10

(Shown in Table 31)

Bits 7, 6, 5, 4 and 3 complete the PDU.

Bits 2, 1, and 0 of byte 9 and bits 7, 6, 5,and 4 of byte 10 are the Source Address for the converter. Each Source Address MUST be unique. SAE J1939-81 describes address management and allocation in detail and should be consulted before connecting to a J1939 bus. Addresses 249 and 250 are designated for offboard diagnostic service tools. WARNING: These addresses are SUGGESTED. The procedure described in SAE J1939-81 should be followed when connecting to any unknown bus.