Internal Functions

While most of the information sent and received from the 1939STB will be transferred to the J1939 bus, the internal function codes allow the user to set up the serial port, and receive an identity string from the 1939STB. The identity string may be used to verify that the 1939STB is connected and working properly.

Vendor String

The vendor string function is sent to the 1939STB as shown in the table below. This function is strictly internal and can be sent to the 1939STB at any time whether or not the 1939STB is connected to an active J1939 bus. The shaded areas are to be set by the user.

Table 9. Vendor String Setup

Byte 1

Byte 2

 

Byte 3

 

 

Byte 4

 

 

 

 

 

 

Nibble 2

 

Nibble 1

 

 

Nibble 2

 

Nibble 1

 

81

21

 

0010

 

0000

 

0000

 

0001

 

81

21

 

 

20hex

 

 

01hex

 

 

 

After this is sent to the 1939STB the device will respond with:

Table 10. Message Received from the SAE-J1939 Bus

I

Function

J1939

 

 

MC

D

 

Address

 

 

4

28

0

0

0

0

00

2

 

0

0

0

0

 

A A

Data

xx xx xx xx xx

xx xx

A A

See “Reception of Data” for an explanation of codes.

The xx may change.

The included Visual Basic application has a script file, VENDN.CVS, that can be sent to the 1939STB to illustrate the vendor string function.