16
Mounting
Mounting Method | Mounting Bracket Installation |
Step 1 : Insert the controller through the panel cutout.
Step 2 : Insert the mounting bracket into the mounting groove at the top and bottom of the controller
Step 3 : Push the mounting bracket forward until the bracket stops at panel wall.
Step 4 : Insert and tighten screws on bracket to secure the controller in place. (The screw torque should be
DTB4824 Mounting Method:
CT Wiring Method (if CT function is selected)
DTB4848/4896/9696 Mounting Method:
3
2
0 6 . 8 m
m
M a x .
17
1
Error Acknowledge and Display
Communication error code response description: |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Error status 102EH/4750H |
| PV read back 1000H/4700H |
| Error status | ||
|
|
|
|
|
|
|
|
|
|
|
| 0001H |
| N/A |
| PV unstable | |
|
|
| 0002H |
| 8002H |
| ||
|
|
| 0003H |
| 8003H |
| Input sensor did not connect | |
|
|
| 0004H |
| 8004H |
| Input signal error | |
|
|
| 0005H |
| N/A |
| Over input range | |
|
|
| 0006H |
| 8006H |
| ADC fail | |
|
|
| 0007H |
| N/A |
| EEPROM read/write error | |
Display message: |
|
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
| Power ON |
|
|
| Normal display | |
| PV |
| DTB series, Firmware V1.50 |
|
| Present value | ||
| SV |
| Output VR type with Event option |
|
| Set value | ||
|
|
| Sensor didn’t connect |
|
|
| Input error | |
| PV |
| No |
|
| Error | ||
| SV |
| Connect |
|
| Input | ||
|
|
|
|
|
|
|
| |
|
|
| EEPROM error |
|
|
| Input over range | |
| PV |
| Error |
|
| PV flash when over | ||
| SV |
| EEPROM |
|
|
|
|
12