B&B Electronics DTB Series Precaution, Display, LED and Pushbuttons, Ordering Information, 1 2 3

Models: DTB Series

1 13
Download 13 pages 49.76 Kb
Page 2
Image 2
B Series Temperature Controller

B Series Temperature Controller

User Manual

PrecautionDisplay, LED and Pushbuttons 1 Ordering Information1 2  3 4

Precaution

DANGER! Caution! Electric Shock!

1.Do not touch the AC terminals while the power is supplied to the controller to prevent an electric shock.

2.Make sure power is disconnected while checking the unit inside.

3.The symbol DTB Series indicates that this Delta B Series Temperature Controller is protected throughout by DOUBLE INSULATION or REINFORCED INSULATION (equivalent to Class II of IEC 536).

Manual background WARNING!

This controller is an open-type temperature controller. Make sure to evaluate any dangerous application in which a serious human injury or serious property damage may occur.

1.Always use recommended solder-less terminals: Fork terminal with isolation (M3 screw, width is 7.0mm (6.0mm for DTB 4824), hole diameter 3.2mm).

Screw size: M3 x 6.5 (With 6.8 x 6.8 square washer). Screw size for DTB4824: M3 x 4.5 (With 6.0 x 6.0 square washer). Recommended tightening

torque: 0.4 N.m (4kgf.cm). Applicable wire: Solid/twisted wire of 2 mm2, 12AWG to 24AWG. Please be sure to tighten them properly.

2.Do not allow dust or foreign objects to fall inside the controller to prevent it from malfunctioning.

3.Never modify or disassemble the controller.

4.Do not connect anything to the “No used” terminals.

5.Make sure all wires are connected to the correct polarity of terminals.

6.Do not install and/or use the controller in places subject to: (a) Dust or corrosive gases and liquid. (b) High humidity and high radiation. (c) Vibration and shock. (d) High voltage and high frequency.

7.Must turn power off when wiring and changing a temperature sensor.

8.Be sure to use compensating wires that match the thermocouple types when extending or connecting the thermocouple wires.

9.Please use wires with resistance when extending or connecting a platinum resistance thermometer (RTD).

10.Please keep the wire as short as possible when wiring a platinum resistance thermometer (RTD) to the controller and please route power wires as far as possible from load wires to prevent interference and induced noise.

11.This controller is an open-type unit and must be placed in an enclosure away from high temperature, humidity, dripping water, corrosive materials, airborne dust and electric shock or vibration.

12.Make sure power cables and signals from instruments are all installed properly before energizing the controller, otherwise serious damage may occur.

13.Please do not touch the terminals in the controller or try to repair the controller when power is applied to prevent an electric shock.

14.Wait at least one minute after power is disconnected to allow capacitors to discharge, and please do not touch any internal circuit within this period.

15.Do not use acid or alkaline liquids for cleaning. Please use a soft, dry cloth to clean the controller.

16.This instrument is not furnished with a power switch or fuse. Therefore, if a fuse or power switch is required, install the protection close to the instrument. Recommended fuse rating: Rated voltage 250 V, Rated current 1 A. Fuse type: Time-lag fuse

17.Note: This controller does not provide overcurrent protection. Use of this product requires that suitable overcurrent protection device(s) must be added to ensure compliance with all relevant electrical standards and codes. (Rated 250 V, 15 Amps max). A suitable disconnecting device should be provided near the controller in the end-use installation.

Manual backgroundManual background 2 Manual backgroundManual background

Display, LED and Pushbuttons

PV Display : to display the process value or parameter type.

SV Display : to display the set point, parameter operation read value, manipulated variable or set value of the parameter.

AT : Auto-tuning LED, flashes when the Auto-tuning operation is ON.

OUT1/OUT2 : Output LED, lights when the output is ON.

Manual background : Function key. Press this key to select the desired function mode and confirm a setting value.

Manual background : Mode key. Press this key to set parameters within function mode. OC, OF : Temperature unit LED.OC : Celsius OF : Fahrenheit

ALM1 ~ ALM3 : Alarm output LED, lights when ALM1/ALM2/ALM3 is ON.

Manual background : Down key. Press this key to decrease values displayed on the SV display. Hold down this key to speed up the decrements.

Manual background :Up key. Press this key to increase values displayed on the SV display. Hold down this key to speed up the incremental action.

Manual backgroundManual background 3 Manual backgroundManual background

Ordering Information

DTB

1Manual backgroundManual background 2 Manual backgroundManual background 3Manual backgroundManual background 4

5 Manual backgroundManual background 6

7

DTB Series

1Manual backgroundManual background 2 Manual backgroundManual background 3Manual backgroundManual background 4 Panel Size (W×H)

51st Output Group Selection

62nd Output Group Selection

7EVENT Inputs /

CT function (Optional)

DTB : Delta B Series Temperature Controller

4824: 1/32 DIN W48 x H24mm; 4848: 1/16 DIN W48 x H48mm;

4896: 1/8 DIN W48 x H96mm; 9696: 1/4 DIN W96 x H96mm

R:Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A

V:Voltage pulse output, 14V +10%~ -20% (Max. 40mA)

C:DC current output, 4 ~ 20m A; L: Linear voltage output, 0~5V, 0~10Vdc

R:Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A

V:Voltage pulse output, 14V +10%~ -20% (Max. 40mA)

None: No EVENT input, No CT (Current transformer); E: EVENT input is provided, No CT (Current transformer)

T: CT (Current transformer) is provided, No EVENT input; V: Valve control.

Note 1: DTB4824 series: no optional function provided and no extra alarm output supported, but user can set 2nd output as alarm mode.

Note 2: DTB4848 series: only one alarm output when optional function supported, but user can set 2nd output as 2nd alarm output.

Note 3: “Valve control” with feedback selection is only available for DTB9696RRV.

1

Page 2
Image 2
B&B Electronics DTB Series user manual Precaution, Display, LED and Pushbuttons, Ordering Information, 1 2 3