39

 

[IP address]

 

radious IP global

radiousip 192.168.1.1

 

 

 

configuration

 

 

 

 

 

 

command to change

 

 

 

 

 

 

the radious server IP.

 

 

 

 

 

 

 

switch(config)# 8021x system

 

8021x system serverport

G

Use the 802.1x system

 

[port ID]

 

server port global

serverport

1815

 

 

 

 

configuration

 

 

 

 

 

 

command to change

 

 

 

 

 

 

the radious server port

 

 

 

 

 

 

 

switch(config)# 8021x system

 

8021x system

G

Use the 802.1x system

 

accountport

 

account port global

accountport

1816

 

 

[port ID]

 

configuration

 

 

 

 

 

 

command to change

 

 

 

 

 

 

the accounting port

 

 

 

 

 

 

 

switch(config)# 8021x system

 

8021x system sharekey

G

Use the 802.1x system

 

[ID]

 

share key global

sharekey 123456

 

 

 

configuration

 

 

 

 

 

 

command to change

 

 

 

 

 

 

the shared key value.

 

 

 

 

 

 

 

switch(config)# 8021x system

 

8021x system nasid

G

Use the 802.1x system

 

[words]

 

nasid global

nasid test1

 

 

 

 

 

configuration

 

 

 

 

 

 

command to change

 

 

 

 

 

 

the NAS ID

 

 

 

 

 

 

 

switch(config)# 8021x misc

 

8021x misc quietperiod

G

Use the 802.1x misc

 

[sec.]

 

quiet period global

quietperiod 10

 

 

 

configuration

 

 

 

 

 

 

command to specify

 

 

 

 

 

 

the quiet period value

 

 

 

 

 

 

of the switch.

 

 

 

 

 

 

 

switch(config)# 8021x misc

 

8021x misc txperiod

G

Use the 802.1x misc

 

[sec.]

 

TX period global

txperiod 5

 

 

 

 

 

configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 