Manuals
/
B&K
/
Computer Equipment
/
Power Supply
B&K
0-30V, 0-3A instruction manual Savi Ranch Parkway Yorba Linda, CA, With Dual LED Display
Models:
0-30V
0-3A
1
3
58
58
Download
58 pages
35.95 Kb
1
2
3
4
5
6
7
8
<
>
Specification
Constant Voltage/Constant Current Characteristic
Fuse Replacement
Warranty
Dimension
Maintenance
Connecting Two Power Supplies in Series
Location of Adjustments
Battery Charging
Setting Current Limit
Page 3
Image 3
Instruction Manual
for
Model 1735A
0-30
V,
0-3
A
DC POWER SUPPLY
With Dual LED Display
22820 Savi Ranch Parkway
Yorba Linda, CA 92887
www.bkprecision.com
3
Page 2
Page 4
Page 3
Image 3
Page 2
Page 4
Contents
MODEL 1735A
El Manual de la Instrucción
0-30V, 0-3A DC POWER SUPPLY With Dual 4-Digit LED Displays
INSTRUCTION MANUAL
TEST INSTRUMENT SAFETY
22820 Savi Ranch Parkway Yorba Linda, CA
Instruction Manual for Model 1735A 0-30 V, 0-3 A DC POWER SUPPLY
With Dual LED Display
TABLE OF CONTENTS
WARRANTY SERVICE INSTRUCTIONS
SPANISH MANUAL
INTRODUCTION
FEATURES
CONSTANT VOLTAGE OPERATION
SPECIFICATIONS
POWER REQUIREMENTS
POWER CONSUMPTION
DIMENSIONS HxWxD
SPECIFICATIONS
TEMPERATURE RANGE
ACCESSORIES SUPPLIED
VOLTAGE CONTROLS
CONTROLS AND INDICATORS
INDICATORS
POWER CONTROLS
Figure 2. Rear Panel
CONTROLS AND INDICATORS REAR PANEL CONTROLS
13. Fuse 14. Power Cord 15. 110/220 Line Voltage Conversion Switch
Figure 1. Front Panel Controls and Indicators
HOOK- UP
OPERATING INSTRUCTIONS
SAFETY PRECAUTIONS
EQUIPMENT PRECAUTIONS
Figure 3 A and B. Grounding Possibilities
OPERATING INSTRUCTIONS
Strap
Strap
Strap
OPERATING INSTRUCTIONS
Figure 3 C and D. Grounding Possibilities
Strap
Load
OPERATING INSTRUCTIONS
TYPICAL CONSTANT VOLTAGE OPERATION
Set Fine VOLTAGE control to center and Coarse VOLTAGE
SETTING CURRENT LIMIT
Figure 5. Setting Current Limit
OPERATING INSTRUCTIONS
Load
OPERATING INSTRUCTIONS
TYPICAL CONSTANT CURRENT OPERATION
2. Determine the desired constant current value
OPERATING INSTRUCTIONS
CONSTANT VOLTAGE/CONSTANT CURRENT CHARACTERISTIC
CONNECTING TWO POWER SUPPLIES IN SERIES
Figure 7. Constant Voltage/Constant Current Characteristic
Figure 8. Connecting Two Power Supplies in Series
Load
OPERATING INSTRUCTIONS
Load
Figure 9. Connecting Two Power Supplies in Parallel
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
CONNECTING TWO POWER SUPPLIES IN PARALLEL
ELECTRONICS MANUFACTURING
APPLICATIONS
GENERAL
ELECTRONICS SERVICING
ELECTRONICS EDUCATION
BATTERY CHARGING
APPLICATION
ELECTRONICS DESIGN LAB
LINE VOLTAGE CONVERSION, INTERNATIONAL UNITS
MAINTENANCE
FUSE REPLACEMENT
ADJUSTMENTS
MAINTENANCE
INSTRUMENT REPAIR SERVICE
1735A CALIBRATION
Figure 11. Location of Adjustments
MAINTENANCE
Page
Service Information
Model Number
Limited Two-Year Warranty
TEST INSTRUMENT SAFETY
SEGURIDAD DE EL INSTRUMENTO DE PRUEBA PRECAUCIONES
Fuente de poder DC Con doble LED indicador
Manual de instrucciones Modelo 1735A
TABLA DE CONTENDIDO
INTRODUCCION
CALIDAD DE LABORATORIO
CARACTERÍSTICAS
0-30 VOTIOS
0-3 AMPERIOS
OPERACIÓN DE CONSTANTE VOLTAJE
ESPECIFICACIONES
VOLTAJE DE SALIDA
CORRIENTE DE SALIDA
Operación
DIMENSIONES AxAxP
ESPECIFICACIONES
RANGO DE TEMPERATURA
CONTROLES DE CORRIENTE
CONTROLES Y INDICADORES
INDICADORES
CONTROLES DE VOLTAJE
Figura 2.Panel trasero
CONTROLES E INDICADORES
CONTROLES DEL PANEL TRASERO 13. Fusible 14. Cordón de poder
Figura 1.Controles e indicadores de el panel delantero
PRECAUCIONES DEL EQUIPO
INSTRUCCIONES DE OPERACION
CONEXIÓN
PRECAUCIONES DE SEGURIDAD
INSTRUCCIONES DE OPERACIÓN
Figura 3 C y D
INSTRUCCIONES DE OPERACIÓN
OPERACION TIPICA DE VOLTAJE CONSTANTE
INSTRUCCIONES DE OPERACIÓN
ESTABLECIENDO EL LIMITE DE CORRIENTE
INSTRUCCIONES DE OPERACIÓN
Figura 6.Tipica operación de corriente
Ponto de gruce
VOLTAJE CONSTANTE/ CORRIENTE CONSTANTE CARACTERISTICAS
Rango de corriente constante
Voltaje
Figura 8 .Conectando dos fuentes de poder en serie
Carga
0.1?
Ajuste ambas fuentes de poder a el mismo voltaje
salida de corriente es igual a la suma de las dos pantallas
Uso de resistores igualadores
CONECTANDO DOS FUENTES DE PODER EN PARALELO
MANUFACTURA DE ELECTRONICA
APLICACIONES
GENERAL
SERVICIO ELECTRONICO
CARGADO DE BATERIA
APLICACIONES
LABORATORIO DE DISENO ELECTRONICO
EDUCACION DE ELECTRONICA
CONVERSION DE LINEA DE VOLTAJE, LINEAS INTERNACIONALES
MANTENIMIENTO
PRECAUCION
REMPLAZO DE FUSIBLE
SERVICIO DE REPARACION DE EL INSTRUMENTO
1735A CALIBRACION
Page
INFORMACION DE SERVICIO
DOS-ANOS DE GARANTIA LIMITADA
SEGURIDAD DE EL EQUIPO DE PRUEBA
B&K Precision Corporation
Product Name DC Power Supplies
Declaration of CE Conformity
according to EEC directives and NF EN 45014 norm
2005 B&K Precision Corp
22820 Savi Ranch Parkway Yorba Linda, CA
481-395-9-001 Printed in Taiwan