Operation

4.5 Performing a Combustion Test

Ensure that the following has been completed, and then proceed with the combustion test as described below:

• Turn ON analyzer and allow it to warm up (Section 4.2).

• Select fuel being burned (Section 4.3).

• Inset probe into stack (Section 4.4).

• If necessary, insert optional primary air thermocouple into combustion- air stream of burners that use an outside source of combustion air.

1. Press the RUN/HOLD button to start the test. You should hear the pump start running and see the word RUN appear at the top of the Combustion Test screen.

2. Press the ENT button to view the various combustion test screens that contain the data listed in Table 4-1 on Page 4-6.

The screens to the right show typical combus- tion test data for an analyzer equipped with O2, COLOW, NO and NO2 sensors.

TIP: Use the zoom-display to show only the values of O2, CO, and efficiency in large char- acters. Refer to Section 3.13.

Sensor Indicators: The following indicators appear in the sensor's data field depending on certain conditions:

(∗ ∗ ∗) Sensor that is not calibrated or defective.

RUN NATURAL GAS

NO

18 ppm

NO2

6 ppm

NOx

24 ppm

NO(3)

19 ppm

NO2(3)

1 ppm

NOx(3)

25 ppm

(XXX) Sensor overrange

PRINT

F1

(- - -) The calculated data cannot be displayed

 

because the measured data necessary to make

 

the calculation is out of range (i.e., oxygen level

O2

above 16%).

3. Press ENT until T-STK is displayed. Loosen

CO

thumbscrew on probe stop and move probe in

 

and out of the stack until the stack’s core tem-

EFF

perature (hot spot) is located as indicated

by the highest T-STK reading; then tighten

 

thumbscrew to prevent further probe move-

F1

ment. Locating the highest stack temperature

 

is very important for accurate efficiency calculations.

MENU

F2

F2

Instruction 24-9448

4-5

Page 39
Image 39
Bacharach 24-9448 manual Eff, Performing a Combustion Test

24-9448 specifications

The Bacharach 24-9448 is a sophisticated instrument designed for detecting and measuring hazardous gases, particularly in environmental and industrial settings. Renowned for its accuracy and reliability, this portable gas analyzer serves a crucial role in ensuring safety and compliance in various applications, including HVAC, refrigeration, and environmental monitoring.

One of the standout features of the 24-9448 is its advanced sensor technology. The device utilizes electrochemical sensors that provide real-time readings of specific gas concentrations, including carbon monoxide, carbon dioxide, and other toxic gases. These sensors are designed to be sensitive and selective, ensuring they deliver precise measurements without interference from other substances in the environment. This is particularly important in industrial settings where multiple gases may be present.

The Bacharach 24-9448 also boasts a user-friendly interface with a clear display that makes it easy for operators to interpret results quickly. The unit features a simple menu navigation system, allowing users to access different functions without hassle. This design consideration enhances usability, especially in high-pressure situations where every second counts.

Portability is another key characteristic of the 24-9448. Weighing in at just a few pounds, it is easy to transport and operate in various locations, whether it be on a job site or in an environmental monitoring scenario. The robust housing is designed to withstand the rigors of fieldwork, ensuring longevity and durability despite challenging conditions.

Moreover, the device includes data logging capabilities, enabling users to store and later review measurements. This feature is essential for compliance documentation and for analyzing trends over time. Users can download data for further analysis, aiding in thorough reporting and decision-making processes.

In addition to its core capabilities, the Bacharach 24-9448 offers flexibility with adjustable calibration settings, accommodating different gas types and concentration ranges. This adaptability ensures it can meet the specific needs of diverse applications, making it a versatile tool in the field.

Overall, the Bacharach 24-9448 is an essential instrument for professionals in various sectors. Its combination of advanced sensor technology, user-friendly design, portability, and data logging capabilities solidifies its position as a leading choice for gas detection and measurement. Whether for routine checks or emergency responses, this analyzer provides the reliability that ensures safety in potentially hazardous environments.