4. Controlling

4.2 Terminology of the RCU controls

1

 

Function keys

 

 

 

 

 

 

 

 

 

F1

 

Source selection

 

 

 

 

 

 

 

F2

 

PIP control setting

 

 

 

 

 

 

 

F3

 

Switch between master source and PIP source

 

 

 

 

 

 

 

F4

 

In VGA mode: White balance

 

 

 

 

 

 

 

F5

 

Shows the RS232 address of the monitor

 

 

 

 

 

2

 

ADJ

 

ADJUST key, to enter the OSD

 

 

 

 

 

3

 

Address key

 

has no function for this monitor

 

 

 

 

 

4

 

Selection key

 

Switch the light sensor on/off

 

 

 

 

 

5

 

PAUSE

 

Change baud rate of the serial interface

 

 

 

 

 

6

 

Standby

 

stand by button, to start the monitor when the power switch is switched on and to

 

 

 

 

switch off the monitor without switching off the power switch.

 

 

 

 

 

7

 

Mute

 

Switch off and on the sound (audio)

 

 

 

 

 

8

 

Help

 

Indicates the resolution of the input video signal

 

 

 

 

 

9

 

Digit buttons

 

0-9: have no function for this monitor

 

 

 

 

 

10

 

Audio controls

 

To control volume, balance, bass and treble of the audio signal

 

 

 

 

 

11

 

Picture controls

 

Except for brightness and contrast, these keys have no function for this monitor

 

 

 

 

 

12

 

PHASE

 

Adjust the phase of the signal

 

 

 

 

 

13

 

Freeze

 

Auto adjust

 

 

 

 

 

14

 

TEXT

 

Switch on/off the 4:3 mode

 

 

 

 

 

15

 

ENTER

 

to confirm an adjustment or selection

 

 

 

 

 

16

 

Cursor Keys

 

to make menu selections in the OSD.

 

 

 

 

RCU

 

 

 

 

cursor key up

 

 

 

 

cursor key down

 

 

 

 

cursor key right

 

 

 

 

cursor key left

 

 

 

 

Use the cursor keys up or right for increasing a value.

 

 

 

 

Use the cursor keys down or left for decreasing a value.

 

 

 

 

 

17

 

EXIT

 

to leave a menu or the OSD

 

 

 

 

 

18

 

RC operating

 

lights up when a button on the remote control is pressed. (This is a visual indicator

 

 

indication

 

to check the operation of the remote control)

How to use the RCU?

Point the front of the RCU directly at the screen.

When using the IR remote control, make sure you are within the effective operating distance (30m, 100ft in a straight line). The remote control unit will not function properly if strong light strikes the sensor window or if there are obstacles between the remote control unit and the IR sensor.

4-4 ___________________________________________________________Barco - LC series - R5976934 - user's manual - Revision 08 - April 2008

Page 40
Image 40
Barco R5976934 user manual Terminology of the RCU controls, How to use the RCU?

R5976934 specifications

The Barco R5976934 is a high-performance projection solution designed primarily for use in medical imaging and clinical applications. This innovative device stands out due to its unique combination of advanced features, cutting-edge technologies, and tailored characteristics that enhance its functionality and user experience.

One of the main features of the R5976934 is its exceptional image quality. It offers high resolution and contrast ratios, ensuring that images are displayed with remarkable clarity, making it ideal for procedures that require precise details, such as surgeries and diagnostics. The device supports a wide color gamut, ensuring that images are rendered with vividness and accuracy, essential for medical imaging where color differentiation can be critical.

In terms of technology, the Barco R5976934 is equipped with an advanced DLP (Digital Light Processing) system, which allows for brilliant brightness levels and improved sharpness. This technology minimizes motion blur, making it suitable for dynamic scenarios in medical environments. Additionally, the projector features Barco’s proprietary Color Boost technology that enhances color performance and consistency across various lighting conditions, ensuring that medical professionals can rely on the accuracy of the displayed images.

The R5976934 also prioritizes user convenience with its easy integration capabilities. The projector supports multiple input formats, making it compatible with various devices such as computers and imaging systems. This flexibility is crucial in a multi-device environment often seen in medical settings. Furthermore, the projector is designed for seamless operation, equipped with user-friendly interfaces that allow quick adjustments and settings modifications, enabling healthcare professionals to focus on what matters most—patient care.

Another notable characteristic is the projector’s durability and reliability. Constructed with robust materials, the R5976934 is designed to withstand the rigorous demands of operating rooms and medical facilities. It also boasts a long operational life and low maintenance requirements, reducing the total cost of ownership over time.

In summary, the Barco R5976934 is an exceptional medical imaging projector that excels in image quality, advanced DLP technology, and ease of use. Its design and features make it an invaluable tool for healthcare professionals, enhancing their ability to deliver precise diagnostics and treatment while ensuring operational efficiency in medical environments.