8. Adjustments
Blanking
Top
Bottom
Left
Right
0
0
0
0
RESET
Enabled Disabled
Image8-20
Use the checkboxes to enable/disable the blanking
Use the Reset key to reset the blanking values.
Thelogo is also affected by the blanking
8.13 Autosetup parametersWhat can be done ?
Theautosetup can be done by using automatic adjustments of following parameters:
• Frequency: adjustautomatically the total number of pixelsof the detected source
• Phase: adjusts automatically the phase of the detected source
• Geometry: adjusts automatically the total number of lines of the selected source
• Gain: adjustsautom aticallythe con trast/brightness settings of the selected source
Allthese parameters can be chosen to be taken in account or not during the Autosetup process, enabling or disabling the options is
done by checking or unchecking the corresponding case.
How to setup ?
1. Press MENU to activate the Toolbar
2. Press →to select Adjustment
3. Press ↓to Pull down the menu
4. Use ↑or ↓to select Autosetup parameters (image 8-21)
5. Press ENTER to activate the function
On the screen appears a dialogbox (image8 -22)
6. Use ↑or ↓to select the desired parameter, a box surrounds the selected item, press ENTER to activate
7. Press MENU or BACK to exit or to go back to the previous menu
60 R5976741 MGP 15 MEDICAL GRADE PROJECTOR 28/04/2004